13.1.2. Removal of the drive of forward screen wipers
Details of installation of a cover of an air inlet
Details of installation of the drive of forward screen wipers
|
- Details of installation of the drive of screenwashes are shown on an illustration to which all references which are found in the text belong.
- Make sure that brushes are stopped in parking situation and remove levers of screen wipers (1) (see the Section Removal and installation of levers of screen wipers).
- Remove from a partition of a motive compartment a rubber sealant (2).
- Release metal clamps (5), give nuts (4) and remove a foam insert.
- Seal a hose of supply of the washing liquid on the control valve.
- Uncover an air inlet (3) complete with the panel of a water reflector (6).
- Uncover an air inlet.
- Release nuts (7) and carefully remove the driving mechanism (8).
- In case of need disconnect an electrical wiring (9) and remove an electric motor (M6/1).
- Installation is made upside-down, - replace the failed sealing elements of a cover of an air inlet, before installation grease the upper edge of a cover and a surface of a windshield with soap solution.
|
|